0086-519-88368688
Category: Other
Introduction: Mechanical DimensionRailroad facility filters are mainly used to suppress electromagnetic interference transmitted along the auxiliary power supply system of high-speed railroad locomotives. It is characterized by high reliability, high filtering perf…
Railroad facility filters are mainly used to suppress electromagnetic interference transmitted along the auxiliary power supply system of high-speed railroad locomotives. It is characterized by high reliability, high filtering performance, high insulation withstand voltage, long operation cycle, wide temperature range, and can work in high altitude, high humidity and heat areas, which can assist all kinds of electronic instruments and equipment in high-speed railroad locomotives to pass the relevant railroad industry EMC standards such as EN 50121-3-2-2017, GB/T 24338.4-2018 and so on.
Type
|
Rated Voltage
|
Rated Curren
|
Leakage Current
|
Technical Indicators
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SF-10EAH1/20 | 440/250V AC | 4×10A | ≤1mA | Insertion loss data see specifications | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SF-10EBH1/40 | 440/250V AC | 3×10A | ≤1mA | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SF-10EBTH1/40 | 440/250V AC | 3×10A | ≤1mA | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SF-20EBH1/40 | 440/250V AC | 3×20A | ≤1mA | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SF-20TH1E/20 | 500V AC | 2×20A | ≤1mA | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SF-20F1/10 | 250V DC | 2×20A | ------ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SF-80F33 | 250V DC | 2×80A | ------ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SF-100F13 | 600V DC | 2×100A | ------ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SF-80EA1 | 440/250V AC | 4×80A | ≤1.5mA | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SF-100EBK7 | 440/250V AC | 3×100A | ≤4.5mA |
Screw specifications | M16×1.5 | M24×1.5 | M33×2.0 | M42×2.0 | M48×2.0 | M60×2.5 | M64×2.5 | M72×3.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Wrench Size | 24mm | 36mm | 50mm | 65mm | 75mm | 90mm | 95mm | 105mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Recommended torque | 20Nm | 25Nm | 30Nm | 30Nm | 30Nm | 35Nm | 35Nm | 40Nm |
Screw specifications | M3 | M4 | M5 | M6 | M8 | M10 | M12 | M14 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Wrench Size | 5.5mm | 7mm | 8mm | 10mm | 13mm | 16mm | 18mm | 21mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Recommended torque | 0.6Nm | 1.5Nm | 2.5Nm | 3.5Nm | 6Nm | 9Nm | 12Nm | 16Nm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Carrying current | 10A | 20A | 42A | 63A | 100A | 150A | 225A | 300A |
Cable Specifications | 1mm2 | 1.5mm2 | 2.5mm2 | 4mm2 | 6mm2 | 10mm2 | 16mm2 | 25mm2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Carrying current | 10A | 15A | 25A | 32A | 42A | 57A | 75A | 100A | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cable Specifications | 35mm2 | 50mm2 | 70mm2 | 95mm2 | 120mm2 | 150mm2 | 185mm2 | 240mm2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Carrying current | 125A | 150A | 200A | 250A | 275A | 300A | 350A | 450A |
Previous: M Series
Next: None
1.Main useMainly used to enter the shielded room signal line transmission, such as telephone lines, fax lines, security m…
(1) Determine the performance index of the filter based on the design requirements;(2) Approaching the performance index …
Often factories use sine wave filters for daily filtering work, while the excellent foil winding structure and aluminum l…
Screenshot, recognize QR code