0086-519-88368688

China Rail Transit EMI/EMC Suppliers

Committed to the EMI / EMC power filter R & D and production focus on electromagnetic compatibility
in the field of product support and service

Products

Other

Location: Home > Products > Other

R Series

Category: Other

Introduction: Mechanical DimensionRailroad facility filters are mainly used to suppress electromagnetic interference transmitted along the auxiliary power supply system of high-speed railroad locomotives. It is characterized by high reliability, high filtering perf…

0086-519-88368688
Inquire
Details Photos

Mechanical Dimension

Railroad facility filters are mainly used to suppress electromagnetic interference transmitted along the auxiliary power supply system of high-speed railroad locomotives. It is characterized by high reliability, high filtering performance, high insulation withstand voltage, long operation cycle, wide temperature range, and can work in high altitude, high humidity and heat areas, which can assist all kinds of electronic instruments and equipment in high-speed railroad locomotives to pass the relevant railroad industry EMC standards such as EN 50121-3-2-2017, GB/T 24338.4-2018 and so on.


Model Selection Table

Type
Rated Voltage
Rated Curren
Leakage Current
Technical Indicators
SF-10EAH1/20 440/250V AC 4×10A ≤1mA Insertion loss data see specifications
SF-10EBH1/40 440/250V AC 3×10A ≤1mA
SF-10EBTH1/40 440/250V AC 3×10A ≤1mA
SF-20EBH1/40 440/250V AC 3×20A ≤1mA
SF-20TH1E/20 500V AC 2×20A ≤1mA
SF-20F1/10 250V DC 2×20A ------
SF-80F33 250V DC 2×80A ------
SF-100F13 600V DC 2×100A ------
SF-80EA1 440/250V AC 4×80A ≤1.5mA
SF-100EBK7 440/250V AC 3×100A ≤4.5mA


Recommended Torque Chart for Installation of Filter Outlet Wave Conduit in Machine Rooms

Screw specifications M16×1.5 M24×1.5 M33×2.0 M42×2.0 M48×2.0 M60×2.5 M64×2.5 M72×3.0
Wrench Size 24mm 36mm 50mm 65mm 75mm 90mm 95mm 105mm
Recommended torque 20Nm 25Nm 30Nm 30Nm 30Nm 35Nm 35Nm 40Nm


Recommended Torque Chart for Power Filter Inlet and Outlet Wiring Bolts

Screw specifications M3 M4 M5 M6 M8 M10 M12 M14
Wrench Size 5.5mm 7mm 8mm 10mm 13mm 16mm 18mm 21mm
Recommended torque 0.6Nm 1.5Nm 2.5Nm 3.5Nm 6Nm 9Nm 12Nm 16Nm
Carrying current 10A 20A 42A 63A 100A 150A 225A 300A


Power Filter Inlet and Outlet Wiring Cable Carrying Current Table

Cable Specifications 1mm2 1.5mm2 2.5mm2 4mm2 6mm2 10mm2 16mm2 25mm2
Carrying current 10A 15A 25A 32A 42A 57A 75A 100A
Cable Specifications 35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240mm2
Carrying current 125A 150A 200A 250A 275A 300A 350A 450A


Photos

Previous: M Series

Next: None

Inquire
Related articles
Main uses and characteristics of signal filters

1.Main useMainly used to enter the shielded room signal line transmission, such as telephone lines, fax lines, security m…

Overall filter design steps

(1) Determine the performance index of the filter based on the design requirements;(2) Approaching the performance index …

Filter operates under harsh conditions

Often factories use sine wave filters for daily filtering work, while the excellent foil winding structure and aluminum l…

Related products
Copyright 2024 Jiangsu Safe Electromagnetic Environment Technology Co., Ltd. Copyright Support: Eastnet
Copyright 2024 Safe Electromagnetic Copyright
XJiangsu Safe Electromagnetic Environment Technology Co., Ltd.

Screenshot, recognize QR code

Safe Electromagnetic

The QR code has been recognized, please scan to add consultation details!
Top