Power line filters for shielded grade facilities

C Series

Category: Power line filters for shielded grade facilities

Introduction: Product FeaturesThe series are suitable for high performance shielded rooms.The leakage current is mA level,and the voltage drop is less than 1V. Electromagnetic shielding effectiveness can up to 100dB at 14KHz to 40GHz.Technical DataSingle phase(Dire…

0086-519-88368688
Inquire
Details Photos

Product Features

The series are suitable for high performance shielded rooms.The leakage current is mA level,and the voltage drop is less than 1V. Electromagnetic shielding effectiveness can up to 100dB at 14KHz to 40GHz.

Technical Data


Single phase(Direct Current)/Three phase power line filters
Rated Voltage VR for two-line filters                250Vac (Live line-zero line)/ 500Vdc (Positive - Negative)

Rated Voltage VR for tour-line filters                440Vac (Live line-zero line) / 250Vac (Positive-Negative)      

Rated current IR                                              See Characteristics (referred to +40℃ ambient temperature)

Rated Frequency FR                                        50/60 Hz /  Direct Current
Test Voltage                                                     1000Vdc/30s ( line - line ) 1000Vdc/30s ( line - ground )
Voltage drop/phase                                          <1V (of VR at 50Hz and IR )
Leakage current I Leakage                                 See Characteristics (at 400/230Vac and 50Hz)
Climate category                                                 25/070/21
❈❈Current range : 16A~1000A( other currents can be customized by contacting us) Current 250A or above is copper wire.

❈❈Voltage range : 36VAC~750VAC/24VDC~1500VDC ( other voltage can be customized )

❈❈Frequency range : DC 50/60Hz 400Hz 800Hz ( other frequencies can be customized )

❈❈DC wiring : DC 2-wire (+,-) DC 3-wire (+,0,-)

❈❈Single-phase wiring : Single-phase AC double wire (L,N) Single-phase AC with ground (L,N,G) Single-phase AC double fire wire (L1,L2)

❈❈Three-phase wiring : Three-phase three-wire (A,B,C) Three-phase four-wire (A,B,C,N) Three-phase five-wire (A,B,C,N,G) 


Shielding Effectiveness 


Model Selection Table

Type
Rated Voltage
Rated Curren
Leakage Current
Shielding Effectiveness
Dim.diagram
SF-2×16C
250V AC
500V DC
2×16A ≤100mA ≥100dB 14kHz~40GHz C01
SF-2×32C 2×32A ≤100mA C01
SF-2×63C 2×63A ≤100mA C02
SF-2×100C 2×100A ≤100mA C03
SF-2×150C 2×150A ≤200mA C04
SF-2×200C 2×200A ≤200mA C04
SF-2×250C 2×250A ≤300mA See specifications for details
SF-2×300C 2×300A ≤300mA See specifications for details
SF-2×400C 2×400A ≤500mA See specifications for details
SF-4×16C 440/250V AC 4×16A ≤100mA ≥100dB 14kHz~40GHz C05
SF-4×32C 4×32A ≤100mA C05
SF-4×63C 4×63A ≤100mA C06
SF-4×100C 4×100A ≤100mA C07
SF-4×150C 4×150A ≤200mA C08
SF-4×200C 4×200A ≤200mA C08
SF-4×250C 4×250A ≤300mA See specifications for details
SF-4×300C 4×300A ≤300mA See specifications for details
SF-4×400C 4×400A ≤500mA See specifications for details


Mechanical Dimension

Contour Drawing number L W H J M S T P D K
C01 F01 450 130 80 -- M24×1.5 -- 385 80 8.2 35
C02 F01 500 145 80 -- M33×2.0 -- 435 80 8.2 35
C03 F01 600 185 90 -- M33×2.0 -- 535 100 8.2 35
C04
F02 800 200 140 830 M33×2.0 90 760 100 9 55
❈❈Please contact us for specific specifications on the external dimensions of high-current products.


Mechanical Dimension


Contour Drawing number L W H J M S T P D K
C05 F03 550 220 80 -- M33×2.0 -- 470 120 8.2 35
C06 F03 650 220 90 -- M33×2.0 -- 570 120 8.2 35
C07 F03 700 240 110 -- M42×2.0 -- 615 140 8.2 40
C08
F04 840 300 130 870 M48×2.0 145 805 200 9 50
❈❈Please contact us for specific specifications on the external dimensions of high-current products.


Ferritic stainless steel shell


This series of power filter adopts stainless steel shell (-SU model suffix), which is mainly equipped with Electromagnetic Wave Anechoic Chamber.The manufacturing process is more environmentally friendly. The shell surface does not need electroless nickel plating. The filter shell can effectively prevent salt spray and corrosion. The incoming and outgoing wires are connected in compartments. While ensuring excellent electromagnetic shielding performance indicators, it has beautiful appearance and reasonable structure.


Model Selection Table

Type

Rated Voltage
Rated Curren
Leakage Current
Shielding
Effectiveness
Dim.diagram
SF-2×16C-SU
250V AC
500V DC
2×16A ≤0.2A ≥100dB 14kHz~40GHz C09
SF-2×32C-SU 2×32A ≤0.2A C09
SF-2×63C-SU 2×63A ≤0.2A C10
SF-2×100C-SU 2×100A ≤0.5A C10
SF-2×150C-SU 2×150A ≤1.0A See specifications for details
SF-2×200C-SU 2×200A ≤1.0A See specifications for details
SF-4×16C-SU 440/250V AC 4×16A ≤0.2A ≥100dB 14kHz~40GHz C11
SF-4×32C-SU 4×32A ≤0.2A C11
SF-4×63C-SU 4×63A ≤0.2A C12
SF-4×100C-SU 4×100A ≤0.5A C12
SF-4×150C-SU 4×150A ≤1.0A See specifications for details
SF-4×200C-SU
4×200A ≤1.0A See specifications for details


Mechanical Dimension

Contour Drawing number L W H F M T1 T2 P D K
C09 F05 500 150 102 190 M24×1.5 300 100 170 6 50
C10 F05 650 190 102 230 M33×2.0 400 150 210 6 50
C11 F06 600 220 102 260 M33×2.0 350 150 240 6 50
C12
F06 650 240 112 280 M42×2.0 400 150 260 6 50
❈❈Please contact us for specific specifications on the external dimensions of high-current products.


Previous: None

Next: CH2 Series

Inquire
Related articles
Main uses and characteristics of signal filters

1.Main useMainly used to enter the shielded room signal line transmission, such as telephone lines, fax lines, security m…

Overall filter design steps

(1) Determine the performance index of the filter based on the design requirements;(2) Approaching the performance index …

Filter operates under harsh conditions

Often factories use sine wave filters for daily filtering work, while the excellent foil winding structure and aluminum l…

Related products
Copyright 2024 Jiangsu Safe Electromagnetic Environment Technology Co., Ltd. Copyright Support: Eastnet
Copyright 2024 Safe Electromagnetic Copyright
XJiangsu Safe Electromagnetic Environment Technology Co., Ltd.

Screenshot, recognize QR code

Safe Electromagnetic

The QR code has been recognized, please scan to add consultation details!
Top